Luteinizing Hormone  (LH)
|
Synonyms:
| LH |
Specimen: | Blood; (1) SST (serum separator) or Red (no preservative) top vacutainer tube. |
Volume: | Full primary tube |
Minimum Volume: | 200 microL serum |
Collection: | If tube other than an SST is collected, transfer serum to a tightly capped plastic aliquot tube within 2 hours of collection for transport.
Stable at room tmeperature for 8 days; refrigerate at 2-8°C for 14 days; freeze for longer storage. |
Rejection Criteria: | Improper labeling. |
Reference Range: | See report. |
Methodology: | Direct chemiluminometric |
Test Use: | The primary clinical use of LH measurement is in evaluating the normalacy of the hypthalamic-pituitary-gonadal axis. Measurement of serum gonadotropin levels will allow for distinguishing between primary gonadal failure and deficient gonadal stimulation. |
Additional Information: | No Additional Information Listed |
Testing Includes: | |
Testing Facility: | AnMed Laboratory |