Lead, Blood (Adult)  (LEAD)
|
Synonyms:
| Pb, Lead |
Specimen: | Blood; (1) Royal Blue (EDTA) top vacutainer tube. |
Volume: | Full primary tube |
Minimum Volume: | |
Collection: | Maintain specimen at room temperature and submit orginal tube for testing. |
Rejection Criteria: | Clotted specimen; improper labeling. |
Reference Range: | Environmental exposure: 0-19 ug/dL Occupational exposure: BEI 30 ug/dL OSHA Lead Standard: 40ug/dLOccupational exposure: BEI : 30 ug/dLOSHA Lead Standard: 40 ug/dL |
Methodology: | Atomic absorption spectrometry (AAS) |
Test Use: | Monitor exposure to lead |
Additional Information: | Sampling time is not critical for occupational exposure (BEI) testing. Blood is the preferred specimen for measurement of acute or recent lead exposure. |
Testing Includes: | Specimen sent to LabCorp. LabCorp test # 007625. |
Testing Facility: | LabCorp |